Porduct application
NTA855 has many uses. It can be equipped with generator sets. For example, it can be equipped with generator sets for ships. It can also be equipped with vehicles. If equipped with vehicles, it is mainly construction machinery, bulldozers, excavators, cranes, etc.For example
Cummins engine for 240kW generator set NT855-G6 Cummins engine used for domestic general purpose ship NT855-M240/NT855-M270/ NT855-M300/NTA855-M350/NTA855-M320/NTA855-M400 Cummins engine for power drive diesel engine NTA855-P320 Cummins engine for D80/D85/T180A bulldozer NT855-C280 Cummins engine for 200KW , 60HZ marine generator set NTA855-G1(M) Cummins engine for 200kW generator set NTA855-G1Now we take NTA855-G1 as an example, analyze the specific parameters of this engine
NTA855-G1 Cummins engine parameters
Engine performance parameters | STANDBY ENGINE | PRIME ENGINE | ||
60HZ | 50HZ | 60HZ | 50HZ | |
Engine speed r/min | 1800 | 1500 | 1800 | 1500 |
Output Power kW(BHP) | 317 | 265 | 287 | 240 |
Mean effective pressure kPa(psi) | 1510 | 1510 | 1358 | 1379 |
Piston average speed m/s(ft/min) | 9.1 | 7.6 | 9.1 | 7.6 |
Maximum parasitic power Kw(HP) | 44 | 33 | 44 | 33 |
Cooling water flow L/s(US gpm) | 7.8 | 6.4 | 7.8 | 6.4 |
Engine parameters with dry exhaust pipe: | ||||
Engine net power kW(BHP) | 302 | 256 | 272 | 231 |
Intake air flow L/s(cfm) | 463 | 345 | 425 | 321 |
Exhaust gas temperature ℃(℉) | 543 | 541 | 460 | 532 |
Exhaust air flow L/s(cfm) | 1253 | 949 | 1029 | 878 |
Radiant heat energy kWm(BTU/min) | 50 | 41 | 45 | 37 |
Cooling water takes away heat kWm(BTU/min) | 202 | 169 | 183 | 153 |
Exhaust takes away heat kWm(BTU/min) | 281 | 233 | 259 | 207 |
Fan air flow L/s(cfm) | 9808 | 8161 | 9808 | 8161 |
Engine parameters with wet exhaust pipe | ||||
Engine net power kW(BHP) | 302 | 256 | 272 | 231 |
Intake air flow L/s(cfm) | 463 | 326 | 425 | 302 |
Exhaust gas temperature ℃(℉) | 496 | 552 | 474 | 510 |
Exhaust air flow L/s(cfm) | 1053 | 852 | 1029 | 753 |
Radiant heat energy kWm(BTU/min) | 41 | 34 | 38 | 31 |
Cooling water takes away heat kWm(BTU/min) | 247 | 206 | 223 | 187 |
Exhaust takes away heat kWm(BTU/min) | 255 | 207 | 220 | 185 |
Fan air flow L/s(cfm) | 9808 | 8161 | 9808 | 8161 |